{"id":297,"date":"2026-01-30T10:31:08","date_gmt":"2026-01-30T10:31:08","guid":{"rendered":"https:\/\/servisi.web.tr\/ariza-kodlari\/?p=297"},"modified":"2026-01-30T10:53:21","modified_gmt":"2026-01-30T10:53:21","slug":"vestel-klima-er16-ariza-kodu","status":"publish","type":"post","link":"https:\/\/servisi.web.tr\/ariza-kodlari\/vestel-klima-er16-ariza-kodu\/","title":{"rendered":"Vestel Klima ER016 Ar\u0131za Kodu"},"content":{"rendered":"<h1 data-start=\"102\" data-end=\"132\"><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-209 aligncenter\" src=\"https:\/\/servisi.web.tr\/ariza-kodlari\/wp-content\/uploads\/2026\/01\/vestel-klima-ariza-kodu-ve-cozumu.png\" alt=\"\" width=\"700\" height=\"700\" srcset=\"https:\/\/servisi.web.tr\/ariza-kodlari\/wp-content\/uploads\/2026\/01\/vestel-klima-ariza-kodu-ve-cozumu.png 700w, https:\/\/servisi.web.tr\/ariza-kodlari\/wp-content\/uploads\/2026\/01\/vestel-klima-ariza-kodu-ve-cozumu-300x300.png 300w, https:\/\/servisi.web.tr\/ariza-kodlari\/wp-content\/uploads\/2026\/01\/vestel-klima-ariza-kodu-ve-cozumu-150x150.png 150w, https:\/\/servisi.web.tr\/ariza-kodlari\/wp-content\/uploads\/2026\/01\/vestel-klima-ariza-kodu-ve-cozumu-250x250.png 250w\" sizes=\"auto, (max-width: 700px) 100vw, 700px\" \/><\/h1>\n<h1 data-start=\"228\" data-end=\"284\">Vestel Er016 Klima Ar\u0131za Kodu Anlama ve \u00c7\u00f6z\u00fcm Rehberi<\/h1>\n<p data-start=\"286\" data-end=\"727\">Vestel kliman\u0131z\u0131n ekran\u0131nda <strong data-start=\"314\" data-end=\"331\">Er016 ar\u0131zas\u0131<\/strong> beliriyorsa, bu genellikle <strong data-start=\"359\" data-end=\"440\">d\u0131\u015f \u00fcnite fan motoru veya s\u0131cakl\u0131k sens\u00f6r\u00fc ile ilgili daha karma\u015f\u0131k bir ar\u0131za<\/strong> anlam\u0131na gelir. Kliman\u0131n kontrol sistemi, d\u0131\u015f \u00fcniteyi g\u00fcvenli s\u0131n\u0131rlar i\u00e7inde \u00e7al\u0131\u015ft\u0131rmak ister; e\u011fer fan \u00e7al\u0131\u015fm\u0131yor veya s\u0131cakl\u0131k sens\u00f6r\u00fc hatal\u0131 veri g\u00f6nderiyorsa cihaz kendini durdurur. Teknik m\u00fcdahale \u00e7o\u011fu zaman gereklidir, ama do\u011fru kontrollerle sorunu h\u0131zla tespit edebilirsiniz.<\/p>\n<h2 data-start=\"729\" data-end=\"762\">Er016 Ar\u0131zas\u0131 Ne Anlama Gelir?<\/h2>\n<p data-start=\"764\" data-end=\"1069\">Er016, Vestel inverter klimalarda <strong data-start=\"798\" data-end=\"841\">d\u0131\u015f \u00fcnite fan motoru veya sens\u00f6r alarm\u0131<\/strong> olarak tan\u0131mlan\u0131r. D\u0131\u015f \u00fcnite fan\u0131, klima devridaim sisteminin so\u011futucu ak\u0131\u015fkan\u0131n\u0131 ve d\u0131\u015f \u00fcniteyi yeterince so\u011futmas\u0131n\u0131 sa\u011flar. Fan motoru veya s\u0131cakl\u0131k sens\u00f6r\u00fc d\u00fczg\u00fcn \u00e7al\u0131\u015fmazsa, cihaz kendini korumak i\u00e7in \u00e7al\u0131\u015fmay\u0131 durdurur.<\/p>\n<p data-start=\"1071\" data-end=\"1108\">Son kullan\u0131c\u0131 a\u00e7\u0131s\u0131ndan belirtiler:<\/p>\n<ul data-start=\"1110\" data-end=\"1261\">\n<li data-start=\"1110\" data-end=\"1161\">\n<p data-start=\"1112\" data-end=\"1161\">Klima a\u00e7\u0131lm\u0131yor veya k\u0131sa s\u00fcre \u00e7al\u0131\u015f\u0131p duruyor.<\/p>\n<\/li>\n<li data-start=\"1162\" data-end=\"1206\">\n<p data-start=\"1164\" data-end=\"1206\">\u0130\u00e7 \u00fcnite ekran\u0131nda Er016 kodu beliriyor.<\/p>\n<\/li>\n<li data-start=\"1207\" data-end=\"1261\">\n<p data-start=\"1209\" data-end=\"1261\">D\u0131\u015f \u00fcnite fan\u0131 \u00e7al\u0131\u015fm\u0131yor veya d\u00fczensiz \u00e7al\u0131\u015f\u0131yor.<\/p>\n<\/li>\n<\/ul>\n<p data-start=\"1263\" data-end=\"1355\">\u00d6zetle, cihaz \u201cd\u0131\u015f \u00fcnite fan\u0131\/sens\u00f6r do\u011fru \u00e7al\u0131\u015fm\u0131yor, g\u00fcvenlik devreye girdi\u201d mesaj\u0131 verir.<\/p>\n<h2 data-start=\"1357\" data-end=\"1396\">Er016 Ar\u0131zas\u0131n\u0131n En Yayg\u0131n Nedenleri<\/h2>\n<p data-start=\"1398\" data-end=\"1466\">Saha tecr\u00fcbeme g\u00f6re Er016 hatas\u0131n\u0131n nedenleri ve g\u00f6r\u00fclme oranlar\u0131:<\/p>\n<div class=\"TyagGW_tableContainer\">\n<div class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\">\n<table class=\"w-fit min-w-(--thread-content-width)\" data-start=\"1468\" data-end=\"2024\">\n<thead data-start=\"1468\" data-end=\"1517\">\n<tr data-start=\"1468\" data-end=\"1517\">\n<th data-start=\"1468\" data-end=\"1476\" data-col-size=\"sm\">Neden<\/th>\n<th data-start=\"1476\" data-end=\"1487\" data-col-size=\"md\">A\u00e7\u0131klama<\/th>\n<th data-start=\"1487\" data-end=\"1517\" data-col-size=\"sm\">Yakla\u015f\u0131k G\u00f6r\u00fclme Oran\u0131 (%)<\/th>\n<\/tr>\n<\/thead>\n<tbody data-start=\"1568\" data-end=\"2024\">\n<tr data-start=\"1568\" data-end=\"1665\">\n<td data-start=\"1568\" data-end=\"1599\" data-col-size=\"sm\">D\u0131\u015f \u00fcnite fan motoru ar\u0131zas\u0131<\/td>\n<td data-start=\"1599\" data-end=\"1658\" data-col-size=\"md\">Fan motoru a\u015f\u0131nm\u0131\u015f, yanm\u0131\u015f veya rotor s\u0131k\u0131\u015fm\u0131\u015f olabilir.<\/td>\n<td data-start=\"1658\" data-end=\"1665\" data-col-size=\"sm\">%35<\/td>\n<\/tr>\n<tr data-start=\"1666\" data-end=\"1765\">\n<td data-start=\"1666\" data-end=\"1703\" data-col-size=\"sm\">D\u0131\u015f \u00fcnite s\u0131cakl\u0131k sens\u00f6r\u00fc ar\u0131zas\u0131<\/td>\n<td data-start=\"1703\" data-end=\"1758\" data-col-size=\"md\">Sens\u00f6r hatal\u0131 veri g\u00f6nderiyor veya kablosu gev\u015femi\u015f.<\/td>\n<td data-start=\"1758\" data-end=\"1765\" data-col-size=\"sm\">%25<\/td>\n<\/tr>\n<tr data-start=\"1766\" data-end=\"1854\">\n<td data-start=\"1766\" data-end=\"1798\" data-col-size=\"sm\">PCB veya fan devresi problemi<\/td>\n<td data-start=\"1798\" data-end=\"1847\" data-col-size=\"md\">Kart fan veya sens\u00f6r sinyalini do\u011fru alam\u0131yor.<\/td>\n<td data-start=\"1847\" data-end=\"1854\" data-col-size=\"sm\">%20<\/td>\n<\/tr>\n<tr data-start=\"1855\" data-end=\"1937\">\n<td data-start=\"1855\" data-end=\"1887\" data-col-size=\"sm\">Kablo veya konekt\u00f6r gev\u015femesi<\/td>\n<td data-start=\"1887\" data-end=\"1930\" data-col-size=\"md\">Fan veya sens\u00f6r kablolar\u0131 tam oturmam\u0131\u015f.<\/td>\n<td data-start=\"1930\" data-end=\"1937\" data-col-size=\"sm\">%10<\/td>\n<\/tr>\n<tr data-start=\"1938\" data-end=\"2024\">\n<td data-start=\"1938\" data-end=\"1966\" data-col-size=\"sm\">Fan pervanesi engellenmi\u015f<\/td>\n<td data-start=\"1966\" data-end=\"2017\" data-col-size=\"md\">Yaprak, ta\u015f veya toz fan\u0131n d\u00f6nmesini engellemi\u015f.<\/td>\n<td data-col-size=\"sm\" data-start=\"2017\" data-end=\"2024\">%10<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<p data-start=\"2026\" data-end=\"2088\">En s\u0131k kar\u015f\u0131la\u015f\u0131lan sorunlar fan motoru ve sens\u00f6r kaynakl\u0131d\u0131r.<\/p>\n<h2 data-start=\"2090\" data-end=\"2122\">Evde Yap\u0131labilecek Kontroller<\/h2>\n<p data-start=\"2124\" data-end=\"2200\">Er016 kodunu g\u00f6rd\u00fc\u011f\u00fcn\u00fczde evde g\u00fcvenli \u015fekilde yapabilece\u011finiz kontroller:<\/p>\n<ul data-start=\"2202\" data-end=\"2468\">\n<li data-start=\"2202\" data-end=\"2233\">\n<p data-start=\"2204\" data-end=\"2233\">Elektrik \u015falterini kapat\u0131n.<\/p>\n<\/li>\n<li data-start=\"2234\" data-end=\"2305\">\n<p data-start=\"2236\" data-end=\"2305\">D\u0131\u015f \u00fcnite etraf\u0131nda fan\u0131n \u00f6n\u00fcn\u00fc kesen cisim olmad\u0131\u011f\u0131ndan emin olun.<\/p>\n<\/li>\n<li data-start=\"2306\" data-end=\"2400\">\n<p data-start=\"2308\" data-end=\"2400\">Kablo ve konekt\u00f6rleri g\u00f6zle kontrol edin; gev\u015fek veya kopuk varsa teknik servise bildirin.<\/p>\n<\/li>\n<li data-start=\"2401\" data-end=\"2468\">\n<p data-start=\"2403\" data-end=\"2468\">Klimay\u0131 tekrar a\u00e7\u0131n ve kodun devam edip etmedi\u011fini g\u00f6zlemleyin.<\/p>\n<\/li>\n<\/ul>\n<p data-start=\"2470\" data-end=\"2599\">\u00d6nemli: Fan motoru, PCB veya sens\u00f6re <strong data-start=\"2507\" data-end=\"2542\">hi\u00e7bir \u015fekilde m\u00fcdahale etmeyin<\/strong>. Evde yap\u0131lacaklar sadece g\u00f6zlem ve basit kontrollerdir.<\/p>\n<h2 data-start=\"2601\" data-end=\"2638\">Ne Zaman Teknik Servis \u00c7a\u011fr\u0131lmal\u0131?<\/h2>\n<ul data-start=\"2640\" data-end=\"2811\">\n<li data-start=\"2640\" data-end=\"2708\">\n<p data-start=\"2642\" data-end=\"2708\">Kod tekrar \u00e7\u0131k\u0131yor ve evde yap\u0131lan kontroller sorunu \u00e7\u00f6zmediyse.<\/p>\n<\/li>\n<li data-start=\"2709\" data-end=\"2769\">\n<p data-start=\"2711\" data-end=\"2769\">D\u0131\u015f \u00fcnite fan\u0131 hi\u00e7 \u00e7al\u0131\u015fm\u0131yor veya d\u00fczensiz \u00e7al\u0131\u015f\u0131yorsa.<\/p>\n<\/li>\n<li data-start=\"2770\" data-end=\"2811\">\n<p data-start=\"2772\" data-end=\"2811\">Sens\u00f6r veya PCB\u2019den \u015f\u00fcpheleniliyorsa.<\/p>\n<\/li>\n<\/ul>\n<p data-start=\"2813\" data-end=\"2998\">Klimay\u0131 zorlamak yerine servis \u00e7a\u011f\u0131rmak, fan, sens\u00f6r ve PCB\u2019nin zarar g\u00f6rmesini \u00f6nler. Teknik servis \u00f6l\u00e7\u00fcm aleti ile fan motorunu, sens\u00f6r\u00fc ve kart\u0131 test eder ve gerekirse de\u011fi\u015fim yapar.<\/p>\n<h2 data-start=\"3000\" data-end=\"3047\">Er016 Ar\u0131zas\u0131n\u0131 \u00d6nlemek \u0130\u00e7in Bak\u0131m \u00d6nerileri<\/h2>\n<ul data-start=\"3049\" data-end=\"3388\">\n<li data-start=\"3049\" data-end=\"3128\">\n<p data-start=\"3051\" data-end=\"3128\">Y\u0131ll\u0131k bak\u0131m s\u0131ras\u0131nda d\u0131\u015f \u00fcnite fan\u0131, pervanesi ve sens\u00f6rler temizlenmeli.<\/p>\n<\/li>\n<li data-start=\"3129\" data-end=\"3217\">\n<p data-start=\"3131\" data-end=\"3217\">Fan motoru ve PCB ba\u011flant\u0131lar\u0131 g\u00f6zle kontrol edilmeli; gev\u015fek kablo varsa s\u0131k\u0131lmal\u0131.<\/p>\n<\/li>\n<li data-start=\"3218\" data-end=\"3302\">\n<p data-start=\"3220\" data-end=\"3302\">D\u0131\u015f \u00fcniteyi yabanc\u0131 cisimlerden ve toz\/ya\u011fmur gibi \u00e7evresel etkenlerden koruyun.<\/p>\n<\/li>\n<li data-start=\"3303\" data-end=\"3388\">\n<p data-start=\"3305\" data-end=\"3388\">Elektrik voltaj\u0131 stabil olmal\u0131; dalgalanma fan ve PCB ar\u0131zalar\u0131n\u0131 tetikleyebilir.<\/p>\n<\/li>\n<\/ul>\n<p data-start=\"3390\" data-end=\"3464\">Bu \u00f6nlemler, Er016 ve benzeri fan\/sens\u00f6r kaynakl\u0131 ar\u0131zalar\u0131n \u00e7o\u011funu \u00f6nler.<\/p>\n<h2 data-start=\"3466\" data-end=\"3488\">S\u0131k Sorulan Sorular<\/h2>\n<p data-start=\"3490\" data-end=\"3599\"><strong data-start=\"3490\" data-end=\"3521\">Er016 ar\u0131zas\u0131 tehlikeli mi?<\/strong><br data-start=\"3521\" data-end=\"3524\" \/>Hay\u0131r, cihaz kendini durdurur ve g\u00fcvenlik devreye girer. Risk olu\u015fturmaz.<\/p>\n<p data-start=\"3601\" data-end=\"3738\"><strong data-start=\"3601\" data-end=\"3640\">Er016 varken klima \u00e7al\u0131\u015ft\u0131r\u0131l\u0131r m\u0131?<\/strong><br data-start=\"3640\" data-end=\"3643\" \/>\u00c7al\u0131\u015ft\u0131rmak \u00f6nerilmez. Fan veya sens\u00f6r ar\u0131zas\u0131 cihaz\u0131 zorlar, PCB veya motor zarar g\u00f6rebilir.<\/p>\n<p data-start=\"3740\" data-end=\"3910\"><strong data-start=\"3740\" data-end=\"3792\">Fan motoru veya sens\u00f6r de\u011fi\u015fimi maliyetli midir?<\/strong><br data-start=\"3792\" data-end=\"3795\" \/>Fan motoru veya sens\u00f6r de\u011fi\u015fimi 2026 fiyatlar\u0131yla 600\u20132.500 TL aras\u0131nda olabilir. Servis \u00f6l\u00e7\u00fcmle net fiyat verir.<\/p>\n<p data-start=\"3912\" data-end=\"4096\"><strong data-start=\"3912\" data-end=\"3957\">Er016 inverter klimalarda s\u0131k m\u0131 g\u00f6r\u00fcl\u00fcr?<\/strong><br data-start=\"3957\" data-end=\"3960\" \/>Evet, inverter klimalarda fan motoru ve sens\u00f6rler hassas oldu\u011fu i\u00e7in voltaj dalgalanmas\u0131 veya kablo gev\u015femesi Er016\u2019y\u0131 tetikleyebilir.<\/p>\n<p data-start=\"4098\" data-end=\"4228\"><strong data-start=\"4098\" data-end=\"4144\">Evde fan veya sens\u00f6r de\u011fi\u015ftirebilir miyim?<\/strong><br data-start=\"4144\" data-end=\"4147\" \/>Hay\u0131r, teknik bilgi ve \u00f6zel alet gerektirir. Yanl\u0131\u015f m\u00fcdahale klimay\u0131 bozabilir.<\/p>\n<p data-start=\"4230\" data-end=\"4347\"><strong data-start=\"4230\" data-end=\"4255\">K\u0131\u015f\u0131n da olabilir mi?<\/strong><br data-start=\"4255\" data-end=\"4258\" \/>Evet, hem so\u011futma hem \u0131s\u0131tma modunda fan veya sens\u00f6r ar\u0131zas\u0131 Er016 kodunu tetikleyebilir.<\/p>\n<hr data-start=\"4349\" data-end=\"4352\" \/>\n<p data-start=\"4354\" data-end=\"4588\">Bu rehberle Vestel Er016 ar\u0131zas\u0131n\u0131n <strong data-start=\"4390\" data-end=\"4471\">ne oldu\u011funu, nedenlerini, evde yap\u0131labilecek kontrolleri ve bak\u0131m \u00f6nerilerini<\/strong> net \u015fekilde \u00f6\u011frenmi\u015f olacaks\u0131n\u0131z. Servis \u00e7a\u011f\u0131rman\u0131z gereken durumlar\u0131 sahici servis tecr\u00fcbeme dayanarak a\u00e7\u0131klad\u0131m.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Vestel Er016 Klima Ar\u0131za Kodu Anlama ve \u00c7\u00f6z\u00fcm Rehberi Vestel kliman\u0131z\u0131n ekran\u0131nda Er016 ar\u0131zas\u0131 beliriyorsa, bu genellikle d\u0131\u015f \u00fcnite fan motoru veya s\u0131cakl\u0131k sens\u00f6r\u00fc ile ilgili daha karma\u015f\u0131k bir ar\u0131za anlam\u0131na gelir. Kliman\u0131n kontrol sistemi, d\u0131\u015f \u00fcniteyi g\u00fcvenli s\u0131n\u0131rlar i\u00e7inde \u00e7al\u0131\u015ft\u0131rmak ister; e\u011fer fan \u00e7al\u0131\u015fm\u0131yor veya s\u0131cakl\u0131k sens\u00f6r\u00fc hatal\u0131 veri g\u00f6nderiyorsa cihaz kendini durdurur. Teknik &hellip;<\/p>\n","protected":false},"author":2,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[19,1],"tags":[],"class_list":["post-297","post","type-post","status-publish","format-standard","hentry","category-klima","category-vestel"],"_links":{"self":[{"href":"https:\/\/servisi.web.tr\/ariza-kodlari\/wp-json\/wp\/v2\/posts\/297","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/servisi.web.tr\/ariza-kodlari\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/servisi.web.tr\/ariza-kodlari\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/servisi.web.tr\/ariza-kodlari\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/servisi.web.tr\/ariza-kodlari\/wp-json\/wp\/v2\/comments?post=297"}],"version-history":[{"count":3,"href":"https:\/\/servisi.web.tr\/ariza-kodlari\/wp-json\/wp\/v2\/posts\/297\/revisions"}],"predecessor-version":[{"id":310,"href":"https:\/\/servisi.web.tr\/ariza-kodlari\/wp-json\/wp\/v2\/posts\/297\/revisions\/310"}],"wp:attachment":[{"href":"https:\/\/servisi.web.tr\/ariza-kodlari\/wp-json\/wp\/v2\/media?parent=297"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/servisi.web.tr\/ariza-kodlari\/wp-json\/wp\/v2\/categories?post=297"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/servisi.web.tr\/ariza-kodlari\/wp-json\/wp\/v2\/tags?post=297"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}